Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-4 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	55
Date	08/04/14
Start Time	11:50:04
Diameter Midpoint
 11.3	409902
 11.8	386628
 12.2	407369
 12.6	425885
 13.1	460116
 13.6	486314
 14.1	513596
 14.6	546084
 15.1	591338
 15.7	627778
 16.3	670790
 16.8	705182
 17.5	747254
 18.1	781713
 18.8	807110
 19.5	839246
 20.2	860637
 20.9	868498
 21.7	879316
 22.5	886723
 23.3	881211
 24.1	863599
 25.0	844317
 25.9	819853
 26.9	797249
 27.9	746725
 28.9	696344
 30.0	647998
 31.1	614146
 32.2	573871
 33.4	549195
 34.6	532196
 35.9	512971
 37.2	506630
 38.5	498048
 40.0	486365
 41.4	465764
 42.9	440201
 44.5	410526
 46.1	381768
 47.8	352740
 49.6	324620
 51.4	297986
 53.3	271879
 55.2	242850
 57.3	211819
 59.4	180523
 61.5	151788
 63.8	127258
 66.1	104911
 68.5	83616.8
 71.0	65003.9
 73.7	50779.2
 76.4	38933.9
 79.1	29921.8
 82.0	22421.4
 85.1	17074.5
 88.2	12667
 91.4	9206.14
 94.7	7213.92
 98.2	5660.64
101.8	4387.29
105.5	3554.89
109.4	2841.29
113.4	2258.22
117.6	1729.69
121.9	1222.88
126.3	967.287
131.0	742.996
135.8	542.377
140.7	392.638
145.9	301.798
151.2	258.813
156.8	192.006
162.5	156.426
168.5	198.834
174.7	139.978
181.1	148.317
187.7	104.215
194.6	99.2978
201.7	84.2002
209.1	74.2093
216.7	79.299
224.7	96.5267
232.9	73.1207
241.4	92.6901
250.3	49.0055
259.5	59.1851
269.0	38.3602
278.8	46.0979
289.0	77.1295
299.6	81.6776
310.6	44.115
322.0	56.7043
333.8	37.6601
346.0	56.4467
358.7	46.821
371.8	33.1244
385.4	36.8521
399.5	24.0842
414.2	23.7901
429.4	16.8962
445.1	27.4775
461.4	28.438
478.3	16.0405
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7039
High Voltage	9971.97
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1081.44
Median(nm)	23.836
Mean(nm)	27.481
Geo. Mean(nm)	24.807
Mode(nm)	22.4679
Geo. Std. Dev.	1.55683
Total Concentration(#/cm)	2.78009e+007
Comment	